Roth Technologies, LLC announces the release of the CathSOLVER™ function add-in for the CathCAD® Standard software with a general availability date of March 1, 2024 for all licensed Users. Since its inception in 2013, the CathCAD® Software has executed over 260,000+ catheter modeling runs executed by licensed Users and includes all Tier 1 medical companies as licensed users.
SAN ANTONIO, Feb. 29, 2024 /PRNewswire-PRWeb/ — Roth Technologies, LLC announces the immediate release of the CathSOLVER™ function add-in for the CathCAD® Standard software for all licensed Users.
- CathCAD® modernized the microcatheter design process in 2012 by solving the forward problem catheter design problem numerically, that is, given the geometry and the physical characteristics of the design, the Software computed the functional characteristics of the design including longitudinal rigidity, flexural rigidity, torsional rigidity, kink radius, and the applicable failure modes.
- CathSOLVER™ solves the inverse catheter design problem, that is, given a set of desired characteristics (ID, OD, number of layers, and desired physical attributes), the Software will compute and provide the “best” design that meets the catheter design requirements. This software update provides near Artificial Intelligence (AI) capability into the CathCAD® software.
Highlights of the CathSOLVER™ Software update include the following:
- The ability to enter the desired numical values of longitudinal ridigity (EA), flexural rigidity (EI), and torsional rigidity (GJ), AND
- The ability to enter weighting factors for the desired values of EA, EI, and GH, allowing the User to guide the Software on the important characteristics of the design, AND
- The ability to enter constraint factors including maximum outside diameter and maximum kink radius, AND
- The ability to select from a list of standard materials that the User wishes to apply to the optimization problem, AND
- The ability to select from a list of braid wires that the User wishes to apply to the optimizaton problem, AND
- The ability to enter design limiting factors that include but not limited to min/max layer thicknesses and min/max pick counts.
When the applicable design parameters are fully developed by the User, the CathSOLVER™ algorithm executes hundred of designs iterations resulting in the Software determining the best design given the User’s defined constraints. This additional functionality allows for the novice designer to become more effective in creating designs that satisfy the required design characteristics. The CathSOLVER™ function is also expected to greatly assist expert catheter designers evaluate their designs as it nearly fully automates the design process which to date was done by a manual, iterative process.
The CathCAD® software allows the User to model multi-layered composite tubing. The Software computes flexural (EI), longitudinal (EA), and torsional (GJ) rigidities and also includes the following additional capabilities:
- Catheter failure mode analysis including tensile strength, torque, kink radius, tube ovalization, and external pressure rating, and
- A “fuse down/lamination” model that may be used to size the correct outer material dimensional requirements, and
- An ovalization model that is used to compute the ovalized (elliptical) shape of a multi-layered composite tube when bent around a series of radiuses, and
- A displacement model that predicts the deflection and angular twist when a multisegment design is subjected to an external load or moment, and
The CathSOLVER™ feature will be made available at no additional charge to existing CathCAD® licensed users and is offered to new customers under the Roth Technologies, LLC standard software licensing terms and conditions.
Since its inception in 2013, the CathCAD® Software has executed over 260,000+ catheter modeling runs executed by licensed Users and includes all Tier 1 medical companies as licensed users. The CathCAD® software has a global client list including customers in the USA, Canada, Ireland, Germany, England, Japan, China, India, and Australia.
Media Contact
R Roth, Roth Technologies, LLC, 1 2103809890, [email protected], www.cathcad.com
View original content to download multimedia:https://www.prweb.com/releases/cathsolver-simplifies-microcatheter-design-development-302076834.html
SOURCE Roth Technologies, LLC